Quick Overview

Climate-Cool® air-cooled aftercoolers, for outdoor installation, use atmospheric air to dissipate heat. No water or electricity is used in cooling and there are no moving parts. Standard models are rated to 4300 SCFM.

Operation:
Hot air from the compressor enters the separator ...



Climate-Cool® air-cooled aftercoolers, for outdoor installation, use atmospheric air to dissipate heat. No water or electricity is used in cooling and there are no moving parts. Standard models are rated to 4300 SCFM.

Operation:
Hot air from the compressor enters the separator / manifold and is divided into smaller streams as it flows through A-shaped cooling arms. Heat is transferred to the tubes and fins and is carried away by moving atmospheric air.

Water condensed during the cooling process falls to the bottom of the separator / manifold on each side of the unit. These large capacity chambers provide an ample claim area and result in minimal pressure drop. The water may be discharged manually or automatically.

Design and Construction:
The cooling arms are large diameter steel tubes fitted with evenly spaced steel fins over the entire length. The unit is fabricated in accordance with the ASME Code, Section VIII. Heavy duty legs are provided for mounting. Maximum working pressure is 150 psig and pressure differential is less than 0.5% of operating pressure.

Capacities:
Six standard models are rated for capacities to 6450 SCFM. For greater volume, modules with identical connections may be combined for the required flow. Two factors which affect capacities are inlet and outlet compressed air temperature and wind velocity. As wind speed increases, the capacity also increases.

Locate column for average wind velocity at proposed installation site and section for maximum inlet air temperature to aftercooler. In that block, read down the column for the desired approach to the flow rate which is the closest to, but does not exceed, the anticipated flow. Read directly across to the model number.

   
O MPH WIND
Approach
5 MPH WIND
Approach
10 MPH WIND
Approach
Air in Temp Model Number 5° F 10° F 15° F 20° F 5° F 10° F 15° F 20° F 5° F 10° F 15° F 20° F
150° F CA-5 70 85 100 120 220 270 360 445 270 375 495 645
  CA-10 135 170 205 245 435 540 720 890 540 750 990 1290
  CA-20 270 340 410 490 870 1080 1440 1780 1080 1500 1980 2580
  CA-30 410 510 620 730 1300 1620 2160 2670 1620 2250 2970 3870
  CA-40 610 765 930 1100 1955 2430 3240 4005 2430 3375 4455 5805
  CA-50 680 850 1030 1220 2170 2700 3600 4450 2700 3750 4950 6450
200° F CA-5 65 80 100 120 200 260 330 400 265 365 460 560
  CA-10 130 165 205 240 405 520 655 800 530 730 920 1120
  CA-20 265 330 410 475 810 1040 1310 1600 1060 1455 1840 2240
  CA-30 395 500 610 715 1220 1560 1970 2400 1590 2185 2760 3360
  CA-40 595 750 920 1070 1830 2340 2950 3600 2385 3275 4140 5040
  CA-50 660 830 1020 1190 2030 2600 3280 4000 2650 3640 4600 5600
250° F CA-5 65 80 100 120 190 255 300 360 260 350 430 510
  CA-10 125 165 200 235 380 510 600 720 520 700 860 1020
  CA-20 250 325 400 470 760 1020 1200 1440 1040 1400 1720 2040
  CA-30 380 490 600 700 1140 1530 1800 2160 1520 2100 2580 3060
  CA-40 570 735 895 1055 1710 2295 2700 3240 2340 3150 3870 4590
  CA-50 630 815 995 1170 1900 2550 3000 3600 2600 3500 4300 5100
300° F CA-5 60 80 100 115 185 240 290 340 250 340 410 485
  CA-10 125 160 195 230 370 480 580 680 500 680 820 970
  CA-20 250 320 390 460 740 960 1160 1360 1000 1360 1640 1940
  CA-30 370 480 580 690 1110 1440 1740 2040 1500 2040 2460 2910
  CA-40 560 720 875 1035 1665 2160 2610 3060 2250 3060 3690 4365
  CA-50 620 800 970 1150 1850 2400 2900 3400 2500 3400 4100 4850
350° F CA-5 60 80 95 110 160 200 240 280 240 325 390 450
  CA-10 120 155 190 220 320 400 480 560 480 650 780 900
  CA-20 240 310 375 440 640 800 960 1120 960 1300 1560 1800
  CA-30 360 460 565 660 960 1200 1440 1680 1440 1950 2340 2700
  CA-40 540 695 845 990 1440 1800 2160 2340 2160 2925 3510 4050
  CA-50 600 770 940 1100 1600 2000 2400 2800 2400 3250 3900 4500

Model Number
Height
A
Width
B
Depth
C
*In / Out
Weight (lbs)
CA-5
11' - 5"
6' - 4 1/2"
25"
8"
800
CA-10
11' - 5"
6' - 4 1/2"
40"
8"
1320
CA-20
11' - 5"
6' - 4 1/2"
70"
8"
2500
CA-30
11' - 9"
8' - 2 5/8"
8' - 2 5/8"
12"
3900
CA-40
11' - 9"
11' - 11 5/8"
11' - 11 5/8"
12"
5250
CA-50
11' - 9"
13' - 2 5/8"
13' - 2 5/8"
12"
5600

*In / Out connections are ANSI CL. 150 R.F. flanges.